Leírás
V2G Split-type Bi-direction Charging Equipment |
According to energy storage power station, interactive smart grid and optimized using of energy resources, EAST developed the new generation of power products, being as bi-direction converter of AC DC, DC AC linked to public power grid in energy storage, photovoltaic, micro network system. Split-type charger consists of bi-direction rectifier cabinet and outdoor charging sets, using modular design, single rectifier module and inverter module being 50kw. It is applicable to charging stations and enterprises’ parking lot.
Split-type public DC charger I: Output voltage range DC 250 V ~ 750 V adjustable, the maximum output power of single unit is 50KW. Split-type public DC charger II: Output voltage range DC 250 V ~ 750 V adjustable, the maximum output power of single unit is 150KW |
● It consists of IGBT converter devices, AC / DC filter devices, soft starter, monitor, isolation transformers and protection devices etc.
● It is featured with power grid peak regulations, improving power grid quality, new energy access and other functions.
MODEL |
EVDC-50KW-V |
EVDC-150KW-V |
INPUT |
||
Input voltage |
260 V ~ 456 V (three phase five wire) |
|
Input current |
≤ 300 A |
|
AC Input frequency |
45 Hz ~ 65 Hz |
|
Efficiency |
||
Power factor |
≥ 0.99 |
|
Input THD |
≤ 5% |
|
DC OUTPUT |
||
Output voltage range |
700 Vdc series:250 V ~750 V |
|
Rated output current |
80 A |
240 A |
Max. output current |
85 A |
250 A |
Soft start time |
3 s ~ 8 s |
|
Output constant-current range |
10% ~ 100% |
|
Voltage regulation accuracy |
≤ ± 0.5% |
|
Current regulation accuracy |
≤ ± 0.5% |
|
Ripple coefficient (peak value) |
≤ 1% |
|
Current-sharing unbalanced degree |
≤ ± 5% (10% ~ 100% rated load) |
|
Noise |
< 55 dB |
|
INVERTER OUTPUT |
||
Output voltage range |
400 V ± 15% (three phase three wire) |
|
Max. efficiency |
≥ 93% |
|
Allowable grid frequency |
47 Hz ~ 51.5 Hz |
|
Power factor |
≥ 0.99 |
|
Output THD |
≤ 5% |
|
THDi |
< 3% (rated power) |
|
Power factor |
0.9 (leading) – 0.9 (lagging) |
|
PROTECTIONS |
||
Output short-circuit protection |
Retraction current ≤ 40% Io; auto-restorable |
|
Output overvoltage protection |
No output after protection; |
|
Input over / under voltage protection |
No output after protection; auto-restorable |
|
Phase-lack protection |
No output after protection; auto-restorable |
|
Overtemperature protection |
No output after protection; auto-restorable |
|
CHARGING CONFIGURATION AND STANDARD |
||
Charging plug number |
/ |
|
Charging cable length (m) |
/ |
|
Communication protocol standard |
GB/T 27930-2015 |
|
Charger standard |
GB/T 18487.1-2015, GB/T 20234.1-2015, GB/T 20234.3-2015, NB/T 33001-2010, NB/T 33008.1-2013 |
|
OTHERS |
||
Operating temperature |
-20℃ ~ + 50℃ |
|
Storage temperature |
-40℃ ~ + 80℃ |
|
Relative humidity |
≤ 95% |
|
Atmospheric pressure |
70 kPa ~ 106 kPa |
|
IP rating |
IP31 |
|
Dimensions (H*W*D) (mm) |
2000*600*600 |
2000*1200*800 |
Weight (kg) |
≤ 620 |
≤ 1500 |
Értékelések