Leírás
EA900Pro 10~30KVA (3:3)EA900Pro 10KVA~30KVA online UPS is an on-line double-conversion UPS with input power factor correction (PFC), output power factor 0.9 offering high levels of reliability and protection for critical servers and data processing IT systems.
● High frequency and true online double-conversion
- DSP digital control technology
- Input power factor correction (PFC)
- Wide input voltage range (190V ~ 485V)
- Output power factor 0.9
- Optimized battery configuration: 192V / 240V
- Cold start
- Auto sensing frequency
- ECO mode operation for energy saving
- 50 / 60 Hz frequency conversion mode
- Selectable output voltage via LCD
- Selectable battery shutdown voltage (EOD) via LCD
- Power-on self test
- Advanced battery management (ABM)
- Short circuit and overload protection
- Automatic charging in OFF mode
- Auto control fan speed when loads varies
- Dual input
- Standard RS232/USB communication port
- Standard emergency power off (EPO)
- Standard maintenance bypass
- Optional extension battery bank
- Optional RS485 / SNMP / AS400 communication port
- Optional N+X redundancy parallel up to 6units
- Optional battery temperature compensation
- Optional battery temperature compensation
- Optional built-in isolation transformer
- Optional manual bypass
MODEL |
EA9010P |
EA9015P |
EA9020P |
EA9030P |
||||
Capacity |
10 KVA / 9 KW |
15 KVA / 13.5 KW |
20 KVA / 18 KW |
30 KVA / 27 KW |
||||
INPUT | ||||||||
Rated voltage |
360 V / 380 V / 400 V / 415 Vac |
|||||||
Voltage range |
277 ~ 485 Vac (no derating) 190 ~ 277 Vac (linear derating between 50% and 100% load) |
|||||||
Rated frequency |
50 / 60 Hz (auto-sense) |
|||||||
Frequency range |
40 ~ 70 Hz |
|||||||
Power factor |
≥ 0.99 |
|||||||
Total harmonic distortion (THDI) |
≤ 5% |
|||||||
Bypass voltage range |
-25% – +15% (settable) |
|||||||
OUTPUT | ||||||||
Voltage |
360 V / 380 V / 400 V / 415 Vac (settable) |
|||||||
Voltage regulation |
± 1% |
|||||||
Frequency |
Synchronized with utility in mains mode; 50 / 60 ± 0.1 Hz in battery mode |
|||||||
Waveform |
Sinusoidal |
|||||||
Crest factor |
3:1 |
|||||||
Total harmonic distortion (THDV) |
≤ 2% (linear load); ≤ 5% (non-linear load) |
|||||||
Transfer time |
0 ms |
|||||||
Inverter overload capability |
102% ~ 125%: transfer to bypass in 10 mins; 125% ~ 150%: transfer to bypass in 1 min; > 150%: transfer to bypass in 0.5 s |
|||||||
Bypass overload capability |
102% ~ 125%: shut down in 20 mins; 125% ~ 150%: shut down in 2 mins; > 150%: shut down in 1 s |
|||||||
BATTERIES | ||||||||
DC voltage |
192 Vdc (option: 240 Vdc) |
|||||||
Inbuilt battery of standard model |
20 × 7 Ah |
40 × 7 Ah |
40 × 9 Ah |
60 × 9 Ah |
||||
Recharge time |
8 h |
|||||||
SYSTEM | ||||||||
Efficiency |
≥ 93%, ECO mode 98% |
|||||||
Display |
LCD + LED |
|||||||
Alarm |
Battery mode, low battery, fans fault etc. |
|||||||
Max. parallel numbers |
6 |
|||||||
EMI |
IEC / EN62040-2 |
|||||||
EMS |
IEC61000-4-2 (ESD) |
|||||||
IEC61000-4-3 (RS) |
||||||||
IEC61000-4-4 (EFT) |
||||||||
IEC61000-4-5 (surge) |
||||||||
COMMUNICATIONS | ||||||||
RS232 / RS485 / USB / dry contacts |
Supports Windows® 98/2000/2003/XP/Vista/2008/7/8/10 |
|||||||
SNMP (optional) |
Power management from SNMP manager and web browser |
|||||||
OTHERS | ||||||||
Humidity |
20 ~ 90% RH @ 0 ~ 40℃ (non-condensing) |
|||||||
Noise level |
≤ 60 dB (1m) |
≤ 65 dB (1m) |
||||||
Dimensions (mm) W × D × H |
350 × 655 × 732 (H) |
|||||||
350 × 785 × 868 (S) |
350 × 785 × 1078 (S) |
|||||||
Packaged dimensions (mm) W×D×H |
472 × 780 × 920 (H) |
|||||||
472 × 910 × 1050 (S) |
472 × 910 × 1260 (S) |
|||||||
Net weight (kg) |
55 (H), 110 (S) |
60 (H), 155 (S) |
61 (H), 175 (S) |
65 (H), 235 (S) |
||||
Gross weight (kg) |
65 (H), 125 (S) |
70 (H), 170 (S) |
71 (H), 190 (S) |
75 (H), 250 (S) |